CDC Test 3

Is this your test? Login to manage it. If not, you can make an exam just like it.

This is a non-interactive preview of the quiz content.

1.
2 points
For odd-sized nuts and bolts, which wrench should you use?
2.
2 points
You need to determine the duration of a waveform with an oscilloscope and a 1X probe.
The seconds/division setting is set at 2ms and the waveform covers 4 division lines. What is the
waveform duration?
3.
2 points
What is the correct way to apply pressure to a file?
4.
2 points
ECRI Institute acts as a supporting agency to help your MTF comply with the Food and
Drug Administration Modernization Act (FDAMA) by handling complaints concerning
5.
2 points
Which common handtools are misused the most?
6.
2 points
The size of an electric drill is usually determined by its
7.
2 points
When using power tools, which procedure is not safe?
8.
2 points
Files used for cutting, removing, smoothing, or polishing metal are categorized by
9.
2 points
Which two screwdrivers are often mistakenly interchanged?
10.
2 points
Which safety procedures are you observing when you wear safety shoes?
11.
2 points
What is the best reason why you should not use a chisel with a mushroomed head?
12.
2 points
When you sweat copper, what could happen if you apply too much flux?
13.
2 points
Minor modifications on a piece of equipment may be authorized by the
14.
2 points
Which wave type would you most likely use to test an amplifier circuit?
15.
2 points
Which materiel complaint do you initiate for design and/or production deficiencies that lead
to unsatisfactory performance and not likely to cause adverse health consequences?
16.
2 points
What is the purpose of using a rubber mat in front of your workbench?
17.
2 points
On a bench grinder, you should adjust the work rest so it is how far from the grinding
wheel?
18.
2 points
Which materiel complaint do you initiate for defects directly responsible for, or are clearly
capable of, causing accident, injury, or death to patients or staff?
19.
2 points
If you are using an oscilloscope probe with a 10X attenuation factor, you can expect signals
below what peak-to-peak voltage level to be difficult to see?
20.
2 points
What three aspects of safety should you consider when using a power tool?
21.
2 points
What should be used in a tool storage area for the safe storage of delicate tools?
22.
2 points
What could happen if you do not use the proper tool to strip wire insulation?
23.
2 points
Which oscilloscope control should you adjust to change the trigger point from the rising
edge to the falling edge of a signal?
24.
2 points
Which oscilloscope function synchronizes the horizontal sweep at the correct point of the
signal and is essential for clear signal characterization?
25.
2 points
The type of report that should be reported to Risk Management as an “incident report”
rather than as a Type I or Type III materiel complaint is a report
26.
2 points
Which device recall is for design and/or production deficiencies that lead to unsatisfactory
performance and not likely to cause adverse health consequences?
27.
2 points
Which materiel complaint category identifies defects that have been directly responsible for,
or are clearly capable of, causing accident or injury to patients or staff?
28.
2 points
You are taking a direct current (DC) voltage measurement with an oscilloscope and a 1X
probe. The volts/division setting is set at 5 and your signal moves upward 3 vertical divisions.
What is the signal voltage?
29.
2 points
How are chisels classified?
30.
2 points
Until it has been repaired or modified, equipment in what recall class must be suspended
from use?
31.
2 points
What form would you use to document the summary of an investigation for a hospital
incident?
32.
2 points
What limits the range of frequencies that can be displayed by an analog oscilloscope?
33.
2 points
What type of pliers do you use for general utility operations?
34.
2 points
Who must you notify of all equipment defects and recall actions taken for equipment in the
medical treatment facility (MTF) inventory?
35.
2 points
When working on printed circuits, what watt soldering pencil is recommended?
36.
2 points
What is the primary tool each shop uses to manage alerts and recalls?
37.
2 points
If you had a waveform with a time duration of 15 milliseconds, what would the frequency
be?
38.
2 points
Soft hammers are designed for
39.
2 points
Why are high-speed drill bits preferred when drilling numerous holes in Bakelite or
plastics?
40.
2 points
Cutting oil is used on a drilling site to
41.
2 points
Which device recall is for defects directly responsible for, or are clearly capable of, causing
accident, injury, or death to patients or staff?
42.
2 points
You are taking a direct current (DC) voltage measurement with an oscilloscope and a 1X
probe. The volts/division setting is set at 2 and your signal moves downward 4.2 vertical
divisions. What is the signal voltage?
43.
2 points
What type of tap do you use to cut full threads to the bottom of a closed hole?
44.
2 points
What precaution should be observed when working with a charged battery cell?
45.
2 points
Modifications of medical devices are normally authorized by the
46.
2 points
The type of pipe that requires little specialized knowledge to work with it is
47.
2 points
Which procedure would not be appropriate when performing an incident investigation
involving an item of medical equipment?
48.
2 points
If you cannot back out a bolt with a screw extractor, what should you do?
49.
2 points
The primary responsibility for compliance with the Food and Drug Administration
Modernization Act (FDAMA) lies with
50.
2 points
As you increase the sweep speed of an analog oscilloscope, you also need to